• date_rangePosted On :   Apr 30' 2007
  • location_cityCity :   San Francisco
  • languageCountry :   USA
  • content_pasteEnquiry No. :   7043031

We are US based company with multiple offices in US, united
Europe and around the world. One of our specialties is
construction materials. Currently we are looking for:
Insulation

Board of mineral wool obtained from stone fibres of lamelled
array of fibres

Classification:
1. Product referring to Polish norm: PN-EN 13162:2002 is
preferable
2. Product referring to United Europe norm: EN-13162:2002 is
perfectly acceptable
3. Hygienic Attest PZH: HK/B/0010/02/2006 must apply, although
we will arrange for the attest
4. Thermal Classification: A1

Required Parameters must be Equal, Similar or Better then:
1. Thermal Conductivity: Fasoterm PF: Alfa D = 0,042 W/mK
2. Identification Code CE for gr 20mm: Fasoterm NF: MW-EN13162-
T5-MU1-AF5
3. Identification Code CE for gr 40-120mm: Fasoterm NF: MW-
EN13162-T5-CS (10/30) - TR80-MU1-AF5
4. Delivery Category: 1200/200

Parameters Thickness [mm] RD
[mm] m2/package [m2K/W]
20 11.52 0.45
50 4.32 1.15
80 2.88 1.90
100 2.40 2.35
120 1.92 2.85

Panel from mineral wool obtained from stone fibres that
additionally possesses marking in the shape of burnt lines on the surface.

Classification:
1. Polish Norm: PN-EN 13162:2002 - preferred
2. United Europe Norm: EN 13162:2002 - perfectly acceptable
3. Hygienic Attest PZH: HK/B/0010/02/2006 - must apply, although
we will arrange for an attest
4. Thermal Classification: A1

Required Parameters must be Equal, Similar or Better then:
1. Thermal Conductivity: Fasoterm PF: AlfaD = 0,040 W/mK
2. Identification Code CE: Fasoterm PF: MW-EN13162-T5-CS
(10/40) - TR15-MU1-AF5
3. Delivery Category: 1000/500

Parameters Thickness [mm] RD
[mm] m2/package [m2K/W]
50 2.00 1.25
80 1.50 2.00
100 1.00 2.50
120 1,00 3.00

Applicable for both products:

Application:
We are requiring a thermal isolation in the light, wet method of
external walls of newly raised buildings and those already
existing as well as underground garages' roofs. It should be
lamelled array of the fibres that makes the wall more elastic and
better fit arched elements of the building walls.

Application of mineral wool for the light, wet method must be
a guarantee of:
- Partition incombustibility,
- Perfect acoustic isolation,
- Proper micro - climate of rooms
- Breathing partitions,
- Size stability,
- Endurance,

CE Certification allowing for export to United Europe is a must.

Required Quantity: 12,500 MT monthly
Transportation: RO-RO on pallets

Note: producers and manufacturers only please.

Sourcing Transparent Packing Films

date_range Dec 14' 2018/  Singapore

We manufacture packaging bags and pouches up to 9 colors and can be customized as per customer’s requirement and design. For further details please make a visit to our...
Wanted Packing Pouches and Bags

date_range Dec 14' 2018/  Singapore

We manufacture packaging bags and pouches up to 9 colors and can be customized as per the customer’s requirement and design. For further details please make a visit to...
Sourcing Packing Foam for Turkey

date_range Dec 14' 2018/  Turkey

We have started to manufacture textile machines in 1989. We also deal in upholstery fabric, textile, narrow weaving, circular knitting, lycra clothes etc. Please make a visit to our website...
Ready to buy Packing Tapes

date_range Dec 14' 2018/  Turkey

We have started to manufacture textile machines in 1989. We also deal in upholstery fabric, textile, narrow weaving, circular knitting, lycra clothes etc. Please make a visit to our website...